Part of the Gothic Fan Vaulting & Conoidal Stone Ribs Topic Directory →

Inverted Conoid Geometry & Tas-de-Charge Springers

Architectural guide to Gothic fan vaulting engineering: inverted conoid curves of revolution, tas-de-charge horizontal masonry, and shear load transfer.

Detailed view of the tas-de-charge masonry courses of a Gothic fan vault showing horizontal stone bedding transitioning into radiating ribs
Structural Springing: Horizontal ashlar tas-de-charge courses anchoring radiating ribs into wall masonry.
Executive Summary & Quick Answer

In Gothic fan vaulting, the inverted conoid is a surface of revolution created by rotating a circular or Tudor profile arc around a vertical pier axis. At its base, where multiple ribs converge, masons construct the tas-de-charge—solid horizontal courses of stone keyed into the exterior wall that act as rigid corbels, effectively shortening the clear vaulted span and mitigating shear stress.

Advertisement

At a Glance: Key Takeaways

  • Conoid Surface of Revolution: Geometrically identical radial ribs ensuring uniform elevation of the upper horizontal bounding circle.
  • Horizontal Tas-de-Charge Bedding: Prevents high diagonal sliding shears by resisting loads through direct vertical compression.
  • Span Shortening Effect: A 2-meter tas-de-charge corbel reduces an 8-meter clear span to a 6-meter active arch span.
  • Point Load Dissipation: Distributes concentrated rib forces across the full masonry thickness of external buttresses.
  • Stereotomy Drafting: Complex 3D stone cutting requiring template extraction from descriptive geometry plan projections.
Engineering diagram contrasting horizontal bedding in tas-de-charge against radiating radial joints in upper conoid voussoirs
Architectural Blueprint: Springing Mechanics: Pier Capital + Horizontal Bedded Tas-de-Charge (2m rise) + Radial Voussoir Transition Line + Conoid Arc.

1. Mathematical Generation of the Inverted Conoid

The geometric genius of the fan vault lies in replacing disparate diagonal, tierceron, and lierne ribs with a continuous mathematical surface: the Inverted Conoid.

Because the generator arc has constant radius \(R\), the rim of the conoid forms a horizontal semi-circle or quarter-circle at the apex height \(H_{\text{apex}}\). The intersection of four adjacent conoids in a square vaulted bay leaves a central flat diamond or square space termed the central spandrel. This horizontal geometry drastically simplifies stone cutting, as every voussoir at a given height tier is identical across all four quadrants.

2. The Tas-de-Charge: Resolving Springing Shear Stresses

If radiating arch voussoirs met directly at the pier capital, the angle between the joint face and horizontal would be nearly \(70^\circ\) to \(80^\circ\). This would create catastrophic sliding shear forces capable of kicking the bottom voussoirs inward.

The master masons countered this through the tas-de-charge (literally 'load bundle'). For the first \(1.5\text{ to }2.5\text{ meters}\) above the capital, all stones are cut with strictly horizontal beds. This ensures that the resultant force from the upper vault bears directly perpendicular to the bedding plane, completely eliminating sliding failure.

3. Thrust Vector Optimization and Middle-Third Kern

The line of thrust passing down through the conoid exits the tas-de-charge into the pier. By extending the tas-de-charge outward into the room, the effective springing point is shifted inward, altering the vector angle:

$$\theta_{\text{resultant}} = \arctan\left(\frac{W_{\text{conoid}} + W_{\text{tas}}}{H_{\text{thrust}}}\right)$$

Because \(W_{\text{tas}}\) adds immense vertical weight directly over the support, \(\theta\) becomes steeper, driving the resultant vector downward inside the middle third of the pier foundation rather than out through its back face.

Advertisement

Conoid & Tas-de-Charge Structural Design Parameters

Use this reference table to calculate exact physical dimensions, ratios, and specifications before purchasing:

Engineering ParameterStructural RequirementTypical Dimension / RangeFailure Mode if Neglected
Conoid Generator ArcUniform circular or 4-centered radiusRadius R = 3.5 to 5.5 mDistorted horizontal spandrel rim; unable to close vault
Tas-de-Charge Height20% to 30% of total bay height1.2 to 2.4 m above capitalSliding shear failure of lowest radial voussoirs
Stone Bed OrientationHorizontal plane ±0.5°0° (parallel to gravity)Bed joint slip under vertical dead loads
Wall Key DepthSolid bonding into wall masonryMinimum 600 mm key into buttressRotational tipping of tas-de-charge corbel into room
Joint Mortar StrengthLow-modulus flexible lime mortarNHL 2.0 (compressive 2.0 MPa)Point crushing of delicate rib filleted edges

Masonry Stereotomy & Site Constraints

Every successful decoration project must account for physical and environmental constraints:

Bedding Plane Orientation

Sedimentary limestone must be laid on its natural bed; carving tas-de-charge stones face-bedded will cause sheets of stone to shear off under load.

Cranage Limits

Single tas-de-charge blocks weigh between 800 kg and 2,500 kg, requiring heavy-duty gantry hoists and rigging within tight cathedral interiors.

Joint Thickness Control

Bed joints must not exceed 4mm; thick lime joints compress unevenly, causing unpredictable vault settlement.

Tas-de-Charge & Conoid Springing Installation

Execute this professional sequence to achieve flawless results without backtracking:

01

Pier Abacus Setting

Level the pier capital stone, checking alignment across all four bay axes with water levels or transit lasers.

02

Tas-de-Charge Template Drafting

Produce 1:1 zinc or plywood templates for each horizontal bed level, transferring the radiating rib profiles.

03

Stone Carving on Natural Bed

Carve monolithic limestone blocks so the natural quarry sedimentary grain lies strictly horizontal in the finished wall.

04

Bedding in Fine Lime Grout

Set each horizontal tas-de-charge course in fine hydraulic lime mortar, checking level and radial projection with plumb lines.

05

Wall Buttress Tie-In

Interlock the rear tail of each tas-de-charge block deep into the exterior ashlar buttress core using lime grout.

06

Transition Course Preparation

Tool the angled top face of the final tas-de-charge course to establish the true radial springing bed for upper conoid voussoirs.

Common Mistakes & Countermeasures

Avoid these costly errors that compromise aesthetics, ergonomics, and budget:

The Pitfall

Carving tas-de-charge stones with face-bedded quarry orientation

Why It Happens: Sedimentary layers run parallel to the exposed face; high compressive stress causes vertical stone spalling and loss of rib profiles.
The Professional Fix: Ensure all limestone blocks are quarried and worked strictly on their natural sedimentary bedding plane.
The Pitfall

Failing to deeply key the rear of the tas-de-charge into the exterior wall buttress

Why It Happens: The stone corbel cantilevers without rear counter-weight, causing it to pivot and crack at the wall junction.
The Professional Fix: Extend the stone tail into the wall core by at least twice the outward projection length.
The Pitfall

Varying the radius of curvature between different ribs on the same conoid

Why It Happens: The conoid surface becomes warped, preventing prefabricated tracery panels from seating flush.
The Professional Fix: Maintain an unyielding single master radius for all ribs radiating from the pier axis.

Project Execution Checklist

0 of 6 completed

Track your physical progress. Checkboxes persist automatically on this device:

Frequently Asked Questions

Why is the tas-de-charge unique to Gothic vaulted architecture?

Roman and Romanesque barrel vaults had continuous thick walls where sliding shear was less concentrated. Gothic architecture reduced walls to skeletal glass openings, concentrating massive compressive and shear forces onto isolated piers, making the tas-de-charge structurally indispensable.

How did medieval masons verify the conoid curve in 3D?

Masons used a rotating wooden trammel arm pivoted on a central vertical iron pin anchored at the pier axis. By swinging the trammel around the 360-degree circle, they checked the distance to every stone surface at any elevation.

Can fan vaulting be executed in reinforced cast stone or plaster today?

Yes. While monumental churches used solid limestone, historicist restorations and luxury residences often employ glass-fiber reinforced gypsum (GFRG) or cast stone panels suspended from structural steel frames.

Related Decoration Guides