Skylight Flashing: Roof Curbs & Condensation Weep Channels

Master leak-free skylight curb flashing: 2x6 raised wood curb geometry, self-adhered EPDM membranes, interlocking aluminum step flashing, and thermal break condensation weep drainage.

Roofer installing aluminum step flashing and self-adhered waterproofing membrane around raised 2x6 skylight roof curb
Zero-Leak Flashing: Wrapping a 2x6 raised curb in rubberized EPDM membrane and woven aluminum step flashing ensures 100% waterproof protection in driving rain.
Executive Summary & Quick Answer

Flash skylight roof curbs by constructing a 2x6 wood curb elevated 4 to 6 inches above the roof deck. Wrap the curb with self-adhered EPDM membrane (lapping 12" onto roof sheathing). Install a bottom apron flashing, weave aluminum step flashing with each shingle course, install a top saddle head flashing, and verify skylight condensation weep channels are unobstructed.

Advertisement

At a Glance: Key Takeaways

  • 4"–6" Minimum Raised Curb Height: Elevates glass frame above pooling water, heavy ice dams, and standing snowpack.
  • Self-Adhered EPDM Ice & Water Membrane: Forms an elastomeric waterproof boot around the curb-to-roof transition.
  • Woven Aluminum Step Flashing (3"×3"×7"): Interleaves with every shingle course so gravity directs runoff around the curb.
  • Top Saddle Head Flashing with 4" Flange: Directs rushing rainwater from upper roof slopes safely around the side step flashings.
  • Internal Condensation Weep Channels: Dual EPDM gasket channels collect indoor glass condensation and weep it outside.
Roof skylight curb cross-section diagram showing 2x6 curb, ice & water shield membrane, bottom apron flashing, step flashing, top saddle flashing, and internal condensation weep channel
Architectural Blueprint: Flashing Architecture: 2x6 Wood Curb + Ice & Water Shield (12" up curb) + Bottom Apron + Woven Step Flashing + Head Flashing + Condensation Weep Channel.

1. Waterproofing Science: 2x6 Raised Curbs & EPDM Underlayment

Over 90% of skylight leaks are not caused by glass failure, but by improper curb construction. Deck-mounted skylights sitting directly on plywood sheathing are easily overwhelmed by ice dams.

Professional roofers build a 2x6 Raised Wood Curb (minimum 4 to 6 inches above roof sheathing). The curb is wrapped in Self-Adhered SBS Modified Bitumen / EPDM Membrane extending 12 inches up the curb and 12 inches out onto the roof deck. Explore splayed geometry in splayed light well angles.

Roofer weaving aluminum step flashing pieces with each row of asphalt roof shingles alongside skylight curb
Interlocking Drainage: Interweaving individual 3x3-inch aluminum step flashing pieces with each shingle row prevents water from migrating sideways under the roof.

2. The Four-Part Flashing System & Internal Condensation Weeps

A leak-free roof installation requires a four-part metal system: Bottom Apron, Side Step Flashing, Top Head Saddle, and Counter-Flashing.

Inside the skylight aluminum frame, engineered Condensation Weep Channels collect moisture droplets that condense on the interior glass face, draining them harmlessly to the outside roof. Review overall layouts in skylight wells hub.

Advertisement

Skylight Mounting Systems Comparison

Use this reference table to calculate exact physical dimensions, ratios, and specifications before purchasing:

Mounting SystemCurb Elevation Above RoofLeak Resistance on Low SlopesLong-Term Serviceability
Curb-Mounted Skylight (Optimal)4" to 6" Raised 2x6 Curb100% Waterproof (Up to 2:12 slopes)Excellent (Replace skylight without re-roofing)
Deck-Mounted Modular FlashingFlush with roof deckModerate (Requires 4:12+ slope)Requires stripping shingles to service
Custom Fabricated Copper Pan Flashing6" to 8" Soldered copper curbExtreme (Commercial 100-year life)High Cost / Master tinsmith required
Direct Mastic-Glued Window (Avoid)0.0" FlatFAILS: Leaks within 12 monthsCatastrophic failure

Top Head Saddle Flashing Ponding Constraints

Every successful decoration project must account for physical and environmental constraints:

Debris and Water Ponding Behind Flat Top Head Saddle of Wide Skylights

Skylights wider than 30 inches trap pine needles and water behind the top curb; build a small pitched wood cricket (saddle) behind the top head curb covered in EPDM membrane to split water runoff to both sides of the skylight.

How to Construct, Flash, and Waterproof a Skylight Roof Curb

Execute this professional sequence to achieve flawless results without backtracking:

1

Build and Fasten 2x6 Wood Curb Box

Construct square 2x6 curb matching manufacturer rough opening; fasten to roof rafters with 3" structural screws.

2

Wrap Self-Adhered EPDM Ice & Water Membrane

Apply membrane 12" onto surrounding roof deck and wrap all the way over top lip of 2x6 curb.

3

Install Bottom Apron Flashing Over Lower Shingles

Nail bottom apron flashing over lower shingle row; fold bottom corners around curb edges.

4

Weave Aluminum Step Flashing with Shingle Rows

Install one 3"×3"×7" step flashing piece with each row of shingles running up both sides of the curb.

5

Install Top Head Saddle Flashing Under Upper Shingles

Slide top saddle flashing under upper roof shingles, overlapping side step flashings by 4 inches.

6

Seat Skylight Frame and Fasten Counter-Flashing

Lower curb-mounted skylight onto curb; drive perimeter gasketed screws into side counter-flashing.

Common Mistakes & Countermeasures

Avoid these costly errors that compromise aesthetics, ergonomics, and budget:

The Pitfall

Nailing Step Flashing Directly into the Vertical Wood Curb

Why It Happens: Nails through vertical step flashing create leak paths when water rushes down the curb.
The Professional Fix: Nail step flashing ONLY into the roof deck sheathing; hold the top vertical leg tight with counter-flashing.

Project Execution Checklist

0 of 4 completed

Track your physical progress. Checkboxes persist automatically on this device:

Frequently Asked Questions

What should you do if an existing skylight sweats and drips water in winter?

Verify that the internal condensation weep channels at the bottom corners of the aluminum frame are not blocked by dirt or paint. Clean weeps with a pipe cleaner, and increase room ventilation to lower indoor relative humidity below 45%.

Related Decoration Guides